ECR 1000

Double conversion on-line UPS from 1 to 10KVA in rack/tower solution

Tecnical detail

Single-phase high-performance uninterruptible power supplies, for small and medium-sized business. They ensure the protection of network equipment, safety systems.

  • On-line UPS from 1 to 10KVA
  • Optimization of the management costs
  • Easy installation and maintenance
  • Configurable for long back-up times



  • On-line double conversion technology: eliminates any noise coming from the mains and ensures maximum reliability.
  • Low management costs: high efficiency and the Eco-mode functionality allow to minimize the operating consumptions.
  • Maximum compatibility with the upstream system, thanks to the active control of the quality of the harmonics and current distortion lower than 3%.
  • User replaceable batteries.
  • Ability to add external battery modules to increase back-up times.
  • Automatic self test with advanced battery management allows to maximize battery performance and service life.
  • Monitoring software. The software, available for Microsoft, Mac and Linux operating systems, allows to control the UPS, to shut it down in the event of a fault and to perform remote diagnostics of the main functions.



  • Input power factor 0.99 and THDi<3%
  • Eco-mode operation for low management costs and low environmental impact.
  • Intelligent cooling allows additional energy savings
  • Full compliance with international product standards.
  • Equipped with programmable outputs to set load priorities.
  • Acoustic alarms in case of power blackout and status changes of the UPS.
  • Free slot to house communication cards.
  • USB port as standard.




 

More info?

Contact us!

Applications

  • Networks & Servers


Category: Tag:

Description

DATA SHEET

 

MODEL

ECR1101

ECR1101SC

ECR1102

ECR1102SC

ECR1103

ECR1103SC

POWER [VA/W] 1000/900 1000/800 2000/1800 2000/1600 3000/2700 3000/2400
INPUT
Rated Voltage 200/208/220/230/240 Vac
Range Voltage 110–300 Vac ± 5%
Range Frequency 40 ÷ 70 Hz
Power factor ≥ 0,99 @ Rated voltage (100% load)
   
OUTPUT
Selectable Voltage 200/208/220/230/240 Vac of 100/110/115/120/127 Vac
Reg. VoltageAC (Batt. Mode) ± 1%
Range Freq.(Synch. Mode) 47÷53 Hz of 57÷63 Hz
Range Freq. (Batt. Mode) 50±0.5 Hz of 60±0.5 Hz
Crest factor 3:1 (max)
Harmonic Distortion ≤ 2% THD (linear load); ≤ 8% (distortion load)
Tempof Transfer Ingressof a Batt. 0 ms
Inverter a Mains Socc. < 4 ms
  EFFICIENCY
Efficiency 90,2 91,1 91,1 91,1 91,2 91,2
  BATTERY
Type AGM 12V / 9Ah External 12V / 9Ah External 12V / 9Ah External
Number 2 4 6
Charge Current (max.) 1 A 8 A 1 A 8 A 1 A 8 A
Load Voltage 27.4 Vdc ± 1% 54.7 Vdc ± 1% 82.1 Vdc ± 1%
  DISPLAY
LCD Display Load and Battery Levels, Operating Modes, SPDT Allarms
  ALARMS
Battery operation Beep every 4 seconds
Low Battery Level Beep every second
Overload Double Beep every second
Generic alarm Beep continuousus
  MECHANICAL
Dimensions (WxDxH) 438 x 380 x 88 [2U] 438 x 480 x 88 [2U] 438 x 600 x 88 [2U]
Weight (kgs) 13 9 21 11 28 14
Noise < 50dB @ 1m
Work environment Temperature 0÷40°C ; Humidity <90%
Interfaccia di Communication USB e RS232; EPO; Intellislot for options SNMP, AS400, ModBus cards

* Reduction of Power tof 95% of nominal when voltage is set tof 115Vac, 90% for voltage at 110Vac and 80% for 110Vac voltage.
** Product specifications may be subject tof change without prior notice.

MODEL

ECR1106

ECR1106SC

ECR1110

ECR1110SC

POWER [VA/W] 6000/5400 10000/9000
INPUT
Rated Voltage 200/208/220/230/240 Vac
Range Voltage 110–300 Vac @ 50% load of 176–300 Vac @ 100% of load
Range Frequency 46 ÷ 64 Hz
Power factor ≥ 0,99 @ Rated voltage (100% load)
   
OUTPUT
Selectable Voltage 200/208/220/230/240 Vac
Reg. VoltageAC (Batt. Mode) ± 1%
Range Freq.(Synch. Mode) 46÷54 Hz of 56÷64 Hz
Range Freq. (Batt. Mode) 50/60 ± 0.1 Hz
Crest factor 3:1 (max.)
Harmonic Distortion ≤ 3% THD (linear load); ≤ 6% (distortion load)
Tempof Transfer Ingressof a Batt. 0 ms
Inverter a Mains Socc. 0 ms
  EFFICIENCY
Efficiency 93,2 93,2 94,2 94,2
  BATTERY
Type AGM 12V / 7Ah External 12V / 9Ah External
Number 20 (selectable 18-20)
Charge Current (max.) 1A 4A 1A 4A
Load Voltage 273 Vdc ± 1% (20 batteries)
  MECHANICAL
Dimensions (WxDxH) ECR1106:
438 x 580 x 133
ECR1106SC:
438 x 580 x 133
ECR1110:
438 x 668 x 133
ECR1110SC:
438 x 668 x 133
  BER1200007:
438 x 580 x 133
BER1200009:
438 x 580 x 133
Weight (kgs) 20 20 24 24
  57 63
Noise < 58dB @ 1m < 60dB @ 1m
Work environment Temperature 0÷40°C ; Humidity <90%
Interfaccia di Communication USB e RS232; Contattof program., EPO; Intellislot for options SNMP, AS400, ModBus

 

Note: Additional cabinet configurations are available. Contact: info@lever.it

Reviews

There are no reviews yet.

Be the first to review “ECR 1000”
TOP